Skip to content
NHA CCMAPractice TestFree test

Free lesson · Clinical Patient Care: Infection Control

Infection control: hand hygiene, PPE and sterilization

Updated November 22, 2026

Infection control breaks the chain of infection. Medical assistants do this with hand hygiene, standard precautions for every patient, and transmission-based precautions when needed. They also clean and disinfect or sterilize equipment according to the risk it carries.

The chain of infection

Infection spreads through six links: infectious agent → reservoir → portal of exit → mode of transmission → portal of entry → susceptible host. Breaking any link stops the spread. Hand hygiene breaks the mode of transmission, and vaccination protects the susceptible host.

Hand hygiene

  • Alcohol-based hand rub is the default in most situations: before and after patient contact, after removing gloves, and before aseptic tasks.
  • Use soap and water when hands are visibly soiled, and after caring for patients with C. difficile or norovirus, because alcohol does not reliably kill spores.
  • Rub with soap for at least 20 seconds, keep the hands lower than the elbows, and turn the faucet off with a paper towel.

Standard vs transmission-based precautions

TypeUsed forKey PPE
StandardEvery patient, every timeGloves, gown and face protection based on the expected exposure
ContactMRSA, C. difficile, scabiesGown and gloves
DropletInfluenza, pertussis, mumpsSurgical mask
AirborneTuberculosis, measles, chickenpoxFit-tested N95 respirator and an airborne isolation room

PPE order

Putting on (donning): gown → mask or respirator → goggles or face shield → gloves.

Taking off (doffing): gloves → goggles or face shield → gown → mask or respirator, then hand hygiene. Gloves come off first because they are the most contaminated. The mask comes off last, outside the room, by the ties.

Sanitize, disinfect, sterilize

  • Sanitization removes visible debris and lowers the number of microbes. It is always the first step before disinfection or sterilization.
  • Disinfection kills most microorganisms but not all spores. It is used for items that touch intact skin, such as stethoscopes and exam tables.
  • Sterilization kills all microorganisms, including spores. It is required for instruments that enter sterile tissue. The office method is the autoclave (steam under pressure, commonly 250°F / 121°C at about 15 psi). Sterilization indicator tape shows an item was exposed to heat; a biological indicator confirms the cycle killed spores.

Sharps and OSHA

Under OSHA's Bloodborne Pathogens Standard, discard used needles right away in a puncture-resistant sharps container. Do not recap them. Replace the container when it is about three-quarters full. Employers must offer the hepatitis B vaccine at no cost to staff exposed to blood.

Check yourself: 5-question quiz

Five reviewed questions on this topic, each with an explanation. Free, no sign-up.

Take the topic quiz

More free lessons