NHA CCMA Practice TestFree test

Free lesson · Clinical Patient Care: EKG

EKG basics: lead placement, waves and artifacts

Updated November 22, 2026

A standard 12-lead EKG uses 10 electrodes: 4 on the limbs and 6 on the chest (V1-V6). The P wave is atrial depolarization, the QRS complex is ventricular depolarization and the T wave is ventricular repolarization.

Chest lead placement

LeadLocation
V14th intercostal space, right sternal border
V24th intercostal space, left sternal border
V3Midway between V2 and V4
V45th intercostal space, left midclavicular line
V5Left anterior axillary line, level with V4
V6Left midaxillary line, level with V4

Limb electrodes go on the arms and legs (RA, LA, RL, LL), on fleshy areas rather than bone. RL is the ground. Prepare the skin by cleaning and drying it so the electrodes stick.

What each part of the waveform means

  • P wave: the atria depolarize (contract).
  • PR interval: the time from atrial to ventricular depolarization, normally 0.12-0.20 seconds.
  • QRS complex: the ventricles depolarize, normally under 0.12 seconds.
  • T wave: the ventricles repolarize (recover).

EKG paper math

At the standard speed of 25 mm/second, one small box is 0.04 seconds and one large box (5 small boxes) is 0.20 seconds. Two quick ways to get the heart rate:

  • 300 rule: 300 ÷ the number of large boxes between two R waves. Three large boxes gives 100 beats a minute.
  • 6-second method: count the R waves in a 6-second strip and multiply by 10. Use this one for irregular rhythms.

Normal sinus rhythm is regular, at 60-100 beats a minute, with one P wave before every QRS.

Artifacts and how to fix them

  • Somatic tremor (jittery baseline): the patient is cold, tense or moving. Keep them warm and relaxed, with limbs supported.
  • Wandering baseline: poor electrode contact, lotion on the skin or breathing movement. Clean the skin and re-apply the electrodes.
  • AC (60-cycle) interference (thick, regular spikes): nearby electrical equipment or crossed lead wires. Unplug nearby devices and straighten the wires.
  • Interrupted baseline: a lead wire or electrode has come loose.

Holter monitor

A Holter monitor records the heart continuously, usually for 24-48 hours. Tell the patient to keep a diary of activities and symptoms, and to avoid getting the monitor wet.

Check yourself: 5-question quiz

Five reviewed questions on this topic, each with an explanation. Free, no sign-up.

Take the topic quiz

More free lessons